Print this Page Print This Page | Print this Page

K-13 Product Specifications


Section 07218 K-13 Spray-On Systems Specification Guide 1003

Download K-13 specifications in pdf format

Download K-13 specifications in word format

PART 1 - GENERAL

1.01 Work Included: (Edit acoustical where required)

Sprayed cellulose thermal [and acoustical] insulation..

1.02 Related Items:

1.03 Quality Assurance:

1.04 Submittals:

1.05 Product Delivery, Storage and Handling:

PART 2 - PRODUCTS

2.01 Acceptable Manufacturers:

2.02 Materials:

  1. Color shall be as indicated in Schedule 3.05.[Color selection will affect price]
  2. Apply at minimum thickness to provide an R-value(s) as indicated in Schedule 3.05. [Add Thermal Resistance values if applicable]
  3. Comply with ASTM E-736 for field-tested bond strength; tested @ > 5 years.
    • Not less than 400 psf
    • Not less than 600 times its weight @ 1"
  4. Comply with ASTM E-84/U.L. 723, Tested at a minimum of 5" thickness Class 1, Class A, Flame Spread 5, Smoke Development 5
  5. Comply with local Building Code requirements.
  6. Comply with ASTM E-1042.
  7. NRC Rating [Edit NRC rating if applicable]: Install at a minimum thickness to achieve a NRC rating as indicated in the Schedule 3.03

  8. Inches 125HZ 250HZ 500HZ 1000HZ 2000HZ 4000HZ NRC
    K-13 Sprayed Thermal and Acoustical Insulation ASTM C-423 on Solid Backing*
    1.00" .08 .29 .75 .98 .93 .96 .75
    1.00** .47 .90 1.10 1.03 1.05 1.03 1.00
    2.00" .26 .68 1.05 1.10 1.03 .98 .95
    3.00 .57 .99 1.04 1.03 1.00 1.00 1.00

    Some values interpolated **On lath

    Inches 125HZ 250HZ 500HZ 1000HZ 2000HZ 4000HZ NRC
    K-13 Sprayed Thermal and Acoustical Insulation Applied at 1.5" Ribbed Metal Deck*
    1.5 .36 .89 1.26 1.07 1.01 1.00 1.05
    3.00" .97 1.04 1.13 .99 .95 .98 1.05

    Some values interpolated **On lath

  9. Non corrosive per ASTM C 739.
  10. Bond Deflection per ASTM E-759: 6" Deflection in 10' Span - No Spalling or Delamination
  11. Cohesive Strength at time of application per Method WS-2000: > 700 Grams

PART 3 - EXECUTION

3.01 Examination

3.02 Preparation

3.03 Installation

3.04 Protection

3.05 Schedule

Provide a schedule when insulation requires listing by color, insulation value, NRC values and attributes.

END OF SECTION